TY - JOUR
T1 - Comparison of four immunoassays for the detection of lorazepam in urine
AU - Meatherall, Robert
AU - Fraser, Albert D.
PY - 1998/12
Y1 - 1998/12
N2 - Four healthy patient subjects were each given a single, 1-mg lorazepam tablet. Urine samples from all patient subjects were collected at 12 intervals (0-2, 2-5, 5-8, 8-11, 11-14, 14-24, 24-26, 26-29, 29-32, 32-35, 35- 38, and 38-48 hours). An aliquot from each urine collection was screened using cloned enzyme donor immunoassay (CEDIA), enzyme-multiplied immunoassay technique (EMIT) II, EMIT dau, and fluorescence polarization immunoassay (FPIA) without and with hydrolysis using [β-glucuronidase. Using a 200 ng/mL calibrator cut-off, none of the four immunoassays gave a positive response before hydrolyzation of the urine samples. For offline hydrolysis using Helix pomatia β-glucuronidase, 35, 3, 0, and 4 of 48 urine samples gave positive responses on the previously listed immunoassays: The CEDIA method also gave 32 of 48 positive responses for online hydrolysis using Escherichia coli β- glucuronidase. Online hydrolysis can be conveniently automated by including the β-glucuronidase in the first of the two reagents combined with the urine sample.
AB - Four healthy patient subjects were each given a single, 1-mg lorazepam tablet. Urine samples from all patient subjects were collected at 12 intervals (0-2, 2-5, 5-8, 8-11, 11-14, 14-24, 24-26, 26-29, 29-32, 32-35, 35- 38, and 38-48 hours). An aliquot from each urine collection was screened using cloned enzyme donor immunoassay (CEDIA), enzyme-multiplied immunoassay technique (EMIT) II, EMIT dau, and fluorescence polarization immunoassay (FPIA) without and with hydrolysis using [β-glucuronidase. Using a 200 ng/mL calibrator cut-off, none of the four immunoassays gave a positive response before hydrolyzation of the urine samples. For offline hydrolysis using Helix pomatia β-glucuronidase, 35, 3, 0, and 4 of 48 urine samples gave positive responses on the previously listed immunoassays: The CEDIA method also gave 32 of 48 positive responses for online hydrolysis using Escherichia coli β- glucuronidase. Online hydrolysis can be conveniently automated by including the β-glucuronidase in the first of the two reagents combined with the urine sample.
UR - http://www.scopus.com/inward/record.url?scp=0031756965&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0031756965&partnerID=8YFLogxK
U2 - 10.1097/00007691-199812000-00016
DO - 10.1097/00007691-199812000-00016
M3 - Article
C2 - 9853986
AN - SCOPUS:0031756965
SN - 0163-4356
VL - 20
SP - 673
EP - 675
JO - Therapeutic Drug Monitoring
JF - Therapeutic Drug Monitoring
IS - 6
ER -