Effect of the arterial oxygenation level on cardiac output, oxygen extraction, and oxygen consumption in low birth weight infants receiving mechanical ventilation

Andreas Schulze, Robin K. Whyte, R. Clifton Way, John C. Sinclair

Research output: Contribution to journalArticlepeer-review

31 Citations (Scopus)

Abstract

Objective: To investigate the effects on oxygenation of targeting the higher versus the lower end of the currently recommended range for pulse oximetry (Sp o 2 ). Design: Nonrandomized crossover trial with the use of within-subject comparisons (two-tailed paired t test). Setting: Level III neonatal intensive care unit of a university hospital. Patients: Twenty infants whose lungs were mechanically ventilated (mean ± SD: birth weight, 1192 ± 396 gm; gestational age, 28.7 ± 2.7 weeks; age at time of study, 42 ± 26 hours). Interventions: The inspired oxygen concentration was adjusted to achieve Sp o 2 readings of 93% to 96% versus 89% to 92% (Ohmeda pulse oximeter) or 95% to 98% versus 91% to 94% (Nellcor oximeter). Measurements: Cardiac output was measured by echocardiography, oxygen content of arterial blood samples by cooximetry, and oxygen consumption by indirect calorimetry. Results: The inspired oxygen concentrations required to achieve the Sp o 2 target ranges were 39.8% ± 8.3% versus 28.7% ± 6.1% ( p <0.001). The respective arterial oxygen contents were 18.0 ± 2.6 ml/dl versus 16.9 ± 2.5 ml/dl ( p <0.001). Oxygen consumption was unchanged. In the lower-oxygen condition no compensatory increase in cardiac output was detected; thus the estimated mixed venous oxygen tension decreased and the oxygen extraction ratio increased. Venous admixture increased from 15% ± 6% to 31% ± 9% in the lower-oxygen condition ( p <0.001). Conclusions: The "low normal" Sp o 2 target range allowed for less oxygen exposure. No signs of mismatch between systemic oxygen delivery and demand could be detected. (J P EDIATR 1995;126:777-84).

Original languageEnglish
Pages (from-to)777-784
Number of pages8
JournalJournal of Pediatrics
Volume126
Issue number5
DOIs
Publication statusPublished - May 1995

Bibliographical note

Funding Information:
Supported in part by Deutsche Forschungsgemeinschaft (A.S.).

ASJC Scopus Subject Areas

  • Pediatrics, Perinatology, and Child Health

Fingerprint

Dive into the research topics of 'Effect of the arterial oxygenation level on cardiac output, oxygen extraction, and oxygen consumption in low birth weight infants receiving mechanical ventilation'. Together they form a unique fingerprint.

Cite this