Factors associated with using an interbody fusion device for low-grade lumbar degenerative versus isthmic spondylolisthesis: A retrospective cohort study

Clayton Inculet, Jennifer C. Urquhart, Parham Rasoulinejad, Hamilton Hall, Charles Fisher, Najmedden Attabib, Kenneth Thomas, Henry Ahn, Michael Johnson, Andrew Glennie, Andrew Nataraj, Sean D. Christie, Alexandra Stratton, Albert Yee, Neil Manson, Jérôme Paquet, Y. Raja Rampersaud, Christopher S. Bailey

Research output: Contribution to journalArticlepeer-review

8 Citations (Scopus)

Abstract

OBJECTIVE Many studies have utilized a combined cohort of patients with degenerative spondylolisthesis (DS) and isthmic spondylolisthesis (IS) to evaluate indications and outcomes. Intuitively, these are very different populations, and rates, indications, and outcomes may differ. The goal of this study was to compare specific patient characteristics associated with the utilization of a posterior lumbar interbody device between cohorts of patients with DS and IS, as well as to compare rates of interbody device use and patient-rated outcomes at 1 year after surgical treatment. METHODS The authors included patients who underwent posterior lumbar interbody fusion or instrumented posterolateral fusion for grade I or II DS or IS and had been enrolled in the Canadian Spine Outcomes and Research Network registry from 2009 to 2016. The outcome measures were score on the Oswestry Disability Index, scores for back pain and leg pain on the numeric rating scale, and mental component summary (MCS) score and physical component summary score on the 12-Item Short-Form Health Survey. Descriptive statistics were used to compare spondylolisthesis groups, logistic regression was used to compare interbody device use, and the chi-square test was used to compare the proportions of patients who achieved a minimal clinically important difference (MCID) at 1 year after surgery. RESULTS In total, 119 patients had IS and 339 had DS. Patients with DS were more commonly women, older, less likely to smoke, and more likely to have neurogenic claudication and comorbidities, whereas patients with IS more commonly had radicular pain, neurological deficits, and worse back pain. Spondylolisthesis was more common at the L4–5 level in patients with DS and at the L5–S1 level in patients with IS. Similar proportions of patients had an interbody device (78.6% of patients with DS vs 82.4% of patients with IS, p = 0.429). Among patients with IS, factors associated with interbody device utilization were BMI ≥ 30 kg/m2 and increased baseline leg pain intensity. Factors associated with interbody device utilization in patients with DS were younger age, increased number of total comorbidities, and lower baseline MCS score. For each outcome measure, similar proportions of patients in the surgical treatment and spondylolisthesis groups achieved the MCID at 1 year after surgery. CONCLUSIONS Although the demographic and patient characteristics associated with interbody device utilization differed between cohorts, similar proportions of patients attained clinically meaningful improvement at 1 year after surgery.

Original languageEnglish
Pages (from-to)299-307
Number of pages9
JournalJournal of Neurosurgery: Spine
Volume35
Issue number3
DOIs
Publication statusPublished - Sept 2021

Bibliographical note

Funding Information:
CSORN is sponsored by the Canadian Spine Education and Research Fund through contributions from Medtronic and DePuy

Publisher Copyright:
© AANS 2021, except where prohibited by US copyright law.

ASJC Scopus Subject Areas

  • Surgery
  • Neurology
  • Clinical Neurology

PubMed: MeSH publication types

  • Journal Article

Fingerprint

Dive into the research topics of 'Factors associated with using an interbody fusion device for low-grade lumbar degenerative versus isthmic spondylolisthesis: A retrospective cohort study'. Together they form a unique fingerprint.

Cite this