Abstract
Otoplasty is a commonly performed procedure to correct prominent ears. Many different otoplasty techniques have been described but there is no gold standard technique. As well, many different suture materials are used in otoplasty but studies directly comparing different sutures materials are lacking. An otoplasty outcome study with Nylon and Mersilene (2 of the most commonly used sutures in otoplasty) sutures was conducted using a rabbit model. Each rabbit ear was randomized to receive a Mustardé-type horizontal mattress suture with either 4-0 clear Nylon (N=12 ears) or 4-0 Mersilene sutures (N=12 ears). Two weeks after surgery, the auricular bend angle was measured with a finger goniometer and histologic analysis with hematoxylin and eosin staining was performed on the rabbit auricular cartilage. Overall, there was no significant difference in the mean bend angle between the 2 groups (Nylon: 135.8°, SD=22.7° and Mersilene: 143.2°, SD=19.7°; P=0.559). Also, no qualitative difference was observed on histologic analysis between the 2 suture groups. In the current rabbit model study, both Nylon and Mersilene sutures performed well and no significant differences were noted.
Original language | English |
---|---|
Pages (from-to) | 477-479 |
Number of pages | 3 |
Journal | Journal of Craniofacial Surgery |
Volume | 27 |
Issue number | 2 |
DOIs | |
Publication status | Published - Mar 23 2016 |
Bibliographical note
Publisher Copyright:© 2016 Mutaz B. Habal, MD.
ASJC Scopus Subject Areas
- Surgery
- Otorhinolaryngology
PubMed: MeSH publication types
- Comparative Study
- Journal Article