TY - JOUR
T1 - Analysis of enzymatically released peptides by reverse-phase high performance liquid chromatography from picomole amounts of apolipoproteins separated on polyacrylamide isoelectric focusing gels
AU - Pereira, L. V.
AU - Dolphin, P. J.
PY - 1982
Y1 - 1982
N2 - Methods were developed for the peptide analysis of individual isoproteins of human apolipoproteins separated on urea-polyacrylamide isoelectric focusing (IEF) gels. After IEF the proteins were fixed in the gel matrix by trichloroacetic acid precipitation. Low molecular weight contaminants, including ampholytes, were removed and the proteins were chemically desialylated. Enzymatic digestions with L-1-tosyl-2-phenylethylchloromethyl ketone - trypsin, chymotrypsin, or with thermolysin were accomplished within the gel matrix. The proteolytically released peptides were analyzed by reverse-phase high performance liquid chromatography. These methods facilitated the comprehensive analysis of protein structural differences between individual isoproteins of apolipoproteins in duplicate with as little as 1-2 nmol of each isoprotein, without the use of radiolabels. Human apolipoproteins A-I, C and E were analysed by these methods.
AB - Methods were developed for the peptide analysis of individual isoproteins of human apolipoproteins separated on urea-polyacrylamide isoelectric focusing (IEF) gels. After IEF the proteins were fixed in the gel matrix by trichloroacetic acid precipitation. Low molecular weight contaminants, including ampholytes, were removed and the proteins were chemically desialylated. Enzymatic digestions with L-1-tosyl-2-phenylethylchloromethyl ketone - trypsin, chymotrypsin, or with thermolysin were accomplished within the gel matrix. The proteolytically released peptides were analyzed by reverse-phase high performance liquid chromatography. These methods facilitated the comprehensive analysis of protein structural differences between individual isoproteins of apolipoproteins in duplicate with as little as 1-2 nmol of each isoprotein, without the use of radiolabels. Human apolipoproteins A-I, C and E were analysed by these methods.
UR - http://www.scopus.com/inward/record.url?scp=0020445166&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0020445166&partnerID=8YFLogxK
U2 - 10.1139/o82-098
DO - 10.1139/o82-098
M3 - Article
C2 - 7127186
AN - SCOPUS:0020445166
SN - 0008-4018
VL - 60
SP - 790
EP - 797
JO - Canadian Journal of Biochemistry
JF - Canadian Journal of Biochemistry
IS - 8
ER -