Automated segmentation of optic nerve head structures with optical coherence tomography

Faisal A. Almobarak, Neil O'Leary, Alexandre S.C. Reis, Glen P. Sharpe, Donna M. Hutchison, Marcelo T. Nicolela, Balwantray C. Chauhan

Producción científica: Contribución a una revistaArtículorevisión exhaustiva

32 Citas (Scopus)

Resumen

Purpose. To quantify and characterize the difference between automated and manual segmentation of optic nerve head structures with spectral-domain optical coherence tomography (SD-OCT). Methods. Optic nerve head radial scans in 107 glaucoma patients and 48 healthy controls were conducted with SD-OCT. Independent segmentations of the internal limiting membrane (ILM) and Bruch's membrane opening (BMO) were performed manually with custom software and with an automated algorithm in each radial scan. The minimum distance between BMO and ILM, termed BMO-minimum rim width (BMO-MRW) was calculated with each segmentation method. Absolute differences between automated and manual segmentations of ILM (ΔILM) and BMO (ΔBMO), and the resulting computation of BMO-MRW (ΔBMO-MRW) were computed. Finally, the relationship between image quality score and ΔILM and ΔBMO was explored. Results. The median (interquartile range, IQR) ΔILM was 8.9 (6.5, 13.4) lm in patients and 7.3 (5.3, 9.9) μm in controls. The corresponding values for DBMO were 11.5 (6.6, 22.1) μm and 12.4 (6.8, 25.4) μm. Subject-averaged ΔILM was higher in patients than controls (P < 0.01); however, mean ΔBMO was not (P = 0.09). The median (IQR) subject-averaged absolute ΔBMO-MRW was 13.4 (10.6, 16.8) μm in patients and 12.1 (10.0, 16.8) μm in controls and not statistically different (P = 0.21). Mean image quality score was statistically higher in controls than patients (P = 0.03) but not related to subject-averaged ΔILM or ΔBMO. Conclusions. In individual scans, the median difference in ILM and BMO segmentations was <2 and <3 image pixels, respectively. There were no differences between patients and controls in ΔBMO-MRW.

Idioma originalEnglish
Páginas (desde-hasta)1161-1168
Número de páginas8
PublicaciónInvestigative Ophthalmology and Visual Science
Volumen55
N.º2
DOI
EstadoPublished - ene. 28 2014

ASJC Scopus Subject Areas

  • Ophthalmology
  • Sensory Systems
  • Cellular and Molecular Neuroscience

Huella

Profundice en los temas de investigación de 'Automated segmentation of optic nerve head structures with optical coherence tomography'. En conjunto forman una huella única.

Citar esto

Almobarak, F. A., O'Leary, N., Reis, A. S. C., Sharpe, G. P., Hutchison, D. M., Nicolela, M. T., & Chauhan, B. C. (2014). Automated segmentation of optic nerve head structures with optical coherence tomography. Investigative Ophthalmology and Visual Science, 55(2), 1161-1168. https://doi.org/10.1167/iovs.13-13310