Detection of Carotid Atherosclerotic Plaque Neovascularization Using Contrast Enhanced Ultrasound: A Systematic Review and Meta-Analysis of Diagnostic Accuracy Studies

Runqing Huang, Sahar S. Abdelmoneim, Caroline A. Ball, Lara F. Nhola, Ann M. Farrell, Steven Feinstein, Sharon L. Mulvagh

Producción científica: Contribución a una revistaArtículo de revisiónrevisión exhaustiva

78 Citas (Scopus)

Resumen

Background Intraplaque neovascularization is considered an important indicator of plaque vulnerability. Contrast-enhanced ultrasound (CEUS) of carotid arteries improves imaging of carotid intima-media thickness and permits real-time visualization of neovascularization of the atherosclerotic plaque. The authors conducted a systematic review and meta-analysis to evaluate the accuracy of CEUS-detected carotid atherosclerotic plaque. Methods A systematic search was performed to identify studies published in the MEDLINE, Embase, Scopus, and Web of Science databases from 2004 to June 2015. Studies evaluating the accuracy of quantitative analysis and qualitative analysis (visual interpretation) for the diagnosis of intraplaque neovascularization compared with histologic specimens and/or clinical diagnosis of symptomatic plaque were included. Parameters evaluated were plaque quantitative CEUS intensity and the visual grading of plaque CEUS. A random-effects meta-analysis was used to pool the likelihood ratios (LRs), diagnostic odds ratios, and summary receiver operating characteristic curves. Corresponding areas under the curves were calculated. Results The literature search identified 203 studies, 20 of which were selected for systematic review; the final meta-analysis included seven studies. For qualitative CEUS, pooled sensitivity was 0.80 (95% CI, 0.72-0.87), pooled specificity was 0.83 (95% CI, 0.76-0.89), the pooled positive LR was 3.22 (95% CI, 1.67-6.18), the pooled negative LR was 0.24 (95% CI, 0.09-0.64), the pooled diagnostic odds ratio was 15.57 (95% CI, 4.94-49.03), and area under the curve was 0.894. For quantitative CEUS, pooled sensitivity was 0.77 (95% CI, 0.71-0.83), pooled specificity was 0.68 (95% CI, 0.62-0.73), the pooled positive LR was 2.34 (95% CI, 1.69-3.23), the pooled negative LR was 0.34 (95% CI, 0.25-0.47), the pooled diagnostic odds ratio was 7.06 (95% CI, 3.6-13.82), and area under the curve was 0.888. Conclusions CEUS is a promising noninvasive diagnostic modality for detecting intraplaque neovascularization. Standardization of quantitative analysis and visual grading classification is needed to increase reliability and reduce technical heterogeneity.

Idioma originalEnglish
Páginas (desde-hasta)491-502
Número de páginas12
PublicaciónJournal of the American Society of Echocardiography
Volumen29
N.º6
DOI
EstadoPublished - jun. 1 2016
Publicado de forma externa

Nota bibliográfica

Publisher Copyright:
© 2016 American Society of Echocardiography.

ASJC Scopus Subject Areas

  • Radiology Nuclear Medicine and imaging
  • Cardiology and Cardiovascular Medicine

Huella

Profundice en los temas de investigación de 'Detection of Carotid Atherosclerotic Plaque Neovascularization Using Contrast Enhanced Ultrasound: A Systematic Review and Meta-Analysis of Diagnostic Accuracy Studies'. En conjunto forman una huella única.

Citar esto