@inproceedings{fa246c8f9b8241e186d290104aa1e3e0,
title = "Direct measurement of basilar membrane motion using pulsed-wave Doppler high-frequency ultrasound",
abstract = "We present a preliminary report on the use of a new technique for measuring the motion of the basilar membrane, high-frequency ultrasound Doppler vibrometry. Using a custom-built, 1 mm diameter probe, we collected ultrasonic reflections from intracochlear structures and applied pulsed-wave Doppler vibrometry to measure the basilar membrane response to pressure applied in the ear canal.",
author = "Z. Torbatian and P. Garland and Adamson, {R. B.A.} and M. Bance and Brown, {J. A.}",
year = "2011",
doi = "10.1063/1.3658125",
language = "English",
isbn = "9780735409750",
series = "AIP Conference Proceedings",
pages = "430--431",
booktitle = "What Fire is in Mine Ears",
note = "11th International Mechanics of Hearing Workshop - What Fire is in Mine Ears: Progress in Auditory Biomechanics ; Conference date: 16-07-2011 Through 22-07-2011",
}