Large radiofrequency ablation lesions can be created with a retractable infusion-needle catheter.

John L. Sapp, Joshua M. Cooper, Paul Zei, William G. Stevenson

Producción científica: Contribución a una revistaArtículorevisión exhaustiva

68 Citas (Scopus)

Resumen

BACKGROUND: Radiofrequency (RF) catheter ablation of ventricular tachycardia is sometimes limited by inadequate lesion depth. We report the use of a novel retractable needle-tipped electrode catheter with intramyocardial (IM) saline infusion and IM RF energy delivery to create large myocardial ablation lesions. METHODS: The left ventricle was entered via the femoral artery in 6 and 11 anesthetized goats and swine (32-90 kg) with an 8-F electrode catheter with an extendable 27-gauge needle at the tip (modified for RF ablation by making the needle electrically active). The needle was advanced 5-7 mm intramyocardially and 0.9% saline was infused 1 mL/min x 60 seconds prior to, and throughout a 120-second application of RF via the active needle, with power titrated to 12 W for 9 lesions, and 30-40 W for 37 lesions, followed by a 120-second RF application using the 4-mm-tip electrode, with power titrated to achieve a 10-Omega decrease in impedance. Needle/saline lesions were compared to 18 standard 4-mm-tip control lesions (power titrated to < or =50 W, to achieve a 10-Omega impedance decrease or limited to 60 degrees Celsius) and to 17 irrigated 3.5-mm-tip lesions (power titrated to < or =50 W, temperature limited to 50 degrees Celsius, 30 mL/min infusion rate). Lesions were identified in the excised heart, fixed, serially sectioned from the endocardium, and digitally analyzed to calculate volume. RESULTS: Lesions were homogeneous and had distinct borders. Compared to 4-mm-tip and irrigated-tip lesions, high-power needle/saline lesions were significantly deeper (13 +/- 2 vs 5 +/- 1 and 8 +/- 3 mm, P < 0.001), had significantly larger volumes (1,700 +/- 750 vs 240 +/- 170 and 750 +/- 650 mm(3), P < 0.001), and had larger cross-sectional area at each millimeter depth beyond the 1 mm (P < 0.01). CONCLUSIONS: IM saline infusion and IM RF energy delivery markedly increase RF lesion size as compared to standard RF ablation and is feasible with a percutaneous catheter. This method warrants further investigation because of its potential clinical utility.

Idioma originalEnglish
Páginas (desde-hasta)657-661
Número de páginas5
PublicaciónJournal of Cardiovascular Electrophysiology
Volumen17
N.º6
DOI
EstadoPublished - jun. 2006

ASJC Scopus Subject Areas

  • Cardiology and Cardiovascular Medicine
  • Physiology (medical)

Huella

Profundice en los temas de investigación de 'Large radiofrequency ablation lesions can be created with a retractable infusion-needle catheter.'. En conjunto forman una huella única.

Citar esto