Resumen
Background and objectives: Catheter ablation of ventricular tachycardia (VT) may include induction of VT and localization of VT-exit site. Our aim was to assess localization performance of a novel statistical pace-mapping method and compare it with performance of an electrocardiographic inverse solution. Methods: Seven patients undergoing ablation of VT (4 with epicardial, 3 with endocardial exit) aided by electroanatomic mapping underwent intraprocedural 120-lead body-surface potential mapping (BSPM). Two approaches to localization of activation origin were tested: (1) A statistical method, based on multiple linear regression (MLR), which required only the conventional 12-lead ECG for a sufficient number of pacing sites with known origin together with patient-specific geometry of the endocardial/epicardial surface obtained by electroanatomic mapping; and (2) a classical deterministic inverse solution for recovering heart-surface potentials, which required BSPM and patient-specific geometry of the heart and torso obtained via computed tomography (CT). Results: For the MLR method, at least 10–15 pacing sites with known coordinates, together with their corresponding 12-lead ECGs, were required to derive reliable patient-specific regression equations, which then enabled accurate localization of ventricular activation with unknown origin. For 4 patients who underwent epicardial mapping, the median of localization error for the MLR was significantly lower than that for the inverse solution (10.6 vs. 27.3 mm, P = 0.034); a similar result held for 3 patients who underwent endocardial mapping (7.7 vs. 17.1 mm, P = 0.017). The pooled localization error for all epicardial and endocardial sites was also significantly smaller for the MLR compared with the inverse solution (P = 0.005). Conclusions: The novel pace-mapping approach to localizing the origin of ventricular activation offers an easily implementable supplement and/or alternative to the preprocedure inverse solution; its simplicity makes it suitable for real-time applications during clinical catheter-ablation procedures.
Idioma original | English |
---|---|
Páginas (desde-hasta) | 979-986 |
Número de páginas | 8 |
Publicación | Journal of Cardiovascular Electrophysiology |
Volumen | 29 |
N.º | 7 |
DOI | |
Estado | Published - jul. 2018 |
Nota bibliográfica
Funding Information:Milan Horacek, Rm 4-P1, Sir Charles Tupper Medical, Building, 5859 University Avenue, Halifax, Nova Scotia B3H 4H7, Canada Email: milan.horacek@dal.ca Funding support was received from Canadian Institutes of Health Research, Heart & Stroke Foundation of Nova Scotia, Biosense-Webster, Haifa, Israel. JohnSappandB.MilanHorácˇekreportparticipa-tion on a research grant supported by Biosense Webster and ownership of a patent relevant to this topic, with rights assigned to Dalhousie University.PetrŠt’ovícˇekreportsownershipof Naviconix, Ltd, UK.
Publisher Copyright:
© 2018 Wiley Periodicals, Inc.
ASJC Scopus Subject Areas
- Cardiology and Cardiovascular Medicine
- Physiology (medical)