Ramped versus stepwise thermoelastic testing of latex and elastic tissues

Sarah M. Wells, Susan M. MacKean

Producción científica: Contribución a conferenciaPapelrevisión exhaustiva

Resumen

Thermoelastic testing assesses the elastic mechanisms of polymers through measurement of the retractive force if) of constrained samples with increasing temperature (T). f contains an entropic (fs) and an internal energy component (fe), where f = fs + fe. The elastic mechanism is normally described by the energetic contribution (fe/f). We have produced a novel thermoelastic testing device capable of performing "stepwise" or "ramped" temperature profiles and have shown excellent agreement between these two techniques for both latex and bovine elastin. Experiments on latex produced an fe/f = 0.18 ± 0.05 (mean ± SD, n=15, ramped protocol) that was independent of extension ratio and temperature. These results demonstrate the highly entropic elastic mechanism in this well-defined material. In agreement with previous studies, the f-T curves for elastin were non-linear, leveling off above ∼60°C. Previous studies quote fe/f for elastin within the 50-70°C range where volume changes (via loss of water) of elastin are thought to be negligible. While we observed a mean fe/f for elastin of 0.18 ± 0.04 at 70 °C (not significantly different from that of latex), the fe/f values for elastin were highly temperature-dependent over the entire experimental temperature range (20-90 °C). These observations may reflect a continuous water loss with increasing temperature in our samples. However, since thermoelastic analysis assumes that force depends only on temperature, other complicating factors must also be considered: e.g. thermal transitions such as microfibril denaturation. These complications call into question the physical meaning of fe/f reported for elastin at any temperature.

Idioma originalEnglish
Páginas206-211
Número de páginas6
EstadoPublished - 2007
Evento44th Annual Rocky Mountain Bioengineering Symposium and 44th International ISA Biomedical Sciences Instrumentation Symposium - Denver, CO, United States
Duración: abr. 13 2007abr. 15 2007

Conference

Conference44th Annual Rocky Mountain Bioengineering Symposium and 44th International ISA Biomedical Sciences Instrumentation Symposium
País/TerritorioUnited States
CiudadDenver, CO
Período4/13/074/15/07

ASJC Scopus Subject Areas

  • Control and Systems Engineering
  • Electrical and Electronic Engineering
  • Computer Science Applications

Huella

Profundice en los temas de investigación de 'Ramped versus stepwise thermoelastic testing of latex and elastic tissues'. En conjunto forman una huella única.

Citar esto