Reducing number of laboratories performing complement dependent cytotoxicity crossmatching: Reasons and conclusions

Prabhakar Putheti, Robert S. Liwski, Peter T. Jindra

Producción científica: Contribución a una revistaArtículorevisión exhaustiva

10 Citas (Scopus)

Resumen

Complement dependent cytotoxicity crossmatch (CDC-XM) has been the original standard crossmatch test, whereas, flow cytometry crossmatch (FCXM) is an enhanced and highly sensitive crossmatch assay performed to detect donor specific anti-HLA antibodies (DSA). We analyzed American Society for Histocompatibility and Immunogenetics (ASHI) proficiency testing data (2011–2020) and examined the number of laboratories performing CDC-XM vs. FCXM, the overall efficiency of laboratories in reporting ≥80% consensus CDC-XM vs. FCXM result, and reasons for non-consensus results in the two assays. Of 600 crossmatches in each crossmatch category, the percentage of laboratories reporting T cell CDC-XMs reduced from 40% in 2011 to 13% in 2020, T cell anti-human globulin (AHG) CDC-XM reduced from 56% in 2011 to 21% in 2020, and B cell CDC-XM reduced from 51% in 2011 to 20% in 2020. The percentage of laboratories performing T cell and B cell FCXM remained at approximately 80% throughout. CDC-XM performed on par with FCXM in providing a consensus negative result using negative DSA serum, but under-performed in comparison to FCXM in providing a consensus positive result using positive DSA serum. In addition, only minority of CDC-XMs was reported positive in presence of complement fixing DSA. This study shows that non-consensus CDC-XM was always in presence of HLA IgG DSA and that laboratories may be struggling to interpret the low sensitive CDC-XM results, where highly sensitive solid phase multi-antigen or single antigen assay shows the presence of HLA IgG DSA in serum.

Idioma originalEnglish
Páginas (desde-hasta)467-475
Número de páginas9
PublicaciónHuman Immunology
Volumen83
N.º5
DOI
EstadoPublished - may. 2022

Nota bibliográfica

Funding Information:
We sincerely thank Ms. Cheryl Hartman, ASHI PT committee liaison for her help with providing critical information needed for the analysis. This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.

Publisher Copyright:
© 2022 American Society for Histocompatibility and Immunogenetics

ASJC Scopus Subject Areas

  • Immunology and Allergy
  • Immunology

PubMed: MeSH publication types

  • Journal Article

Huella

Profundice en los temas de investigación de 'Reducing number of laboratories performing complement dependent cytotoxicity crossmatching: Reasons and conclusions'. En conjunto forman una huella única.

Citar esto