Respiratory modeling in infants: Parameter sensitivity and right-to-left shunt

S. T. Nugent, G. A. Tan, J. P. Finley

Producción científica: Contribución a conferenciaPapelrevisión exhaustiva

2 Citas (Scopus)

Resumen

A mathematical model of the infant respiratory system has been developed and used to investigate the sensitivity of the system to changes in values of the system parameters. The model has been extended to account for right-to-left shunts of the circulation. It was shown that with appropriate parameter values the model can be used to study the effect of various amounts of shunting on the values of system variables such as PaO2.

Idioma originalEnglish
Páginas1811-1813
Número de páginas3
DOI
EstadoPublished - 1988
EventoProceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society - New Orleans, LA, USA
Duración: nov. 4 1988nov. 7 1988

Conference

ConferenceProceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society
CiudadNew Orleans, LA, USA
Período11/4/8811/7/88

ASJC Scopus Subject Areas

  • General Engineering

Huella

Profundice en los temas de investigación de 'Respiratory modeling in infants: Parameter sensitivity and right-to-left shunt'. En conjunto forman una huella única.

Citar esto

Nugent, S. T., Tan, G. A., & Finley, J. P. (1988). Respiratory modeling in infants: Parameter sensitivity and right-to-left shunt. 1811-1813. Papel presentado en Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, New Orleans, LA, USA. https://doi.org/10.1109/iembs.1988.95046