Background: Frame registration is a critical step to ensure accurate electrode placement in stereotactic procedures such as stereoelectroencephalography (SEEG) and is routinely done by merging a computed tomography (CT) scan with the preoperative magnetic resonance (MR) examination. Three-dimensional fluoroscopy (XT) has emerged as a method for intraoperative electrode verification following electrode implantation and more recently has been proposed as a registration method with several advantages. Methods: We compared the accuracy of SEEG electrode placement by frame registration with CT and XT imaging by analyzing the Euclidean distance between planned and post-implantation trajectories of the SEEG electrodes to calculate the error in both the entry (EP) and target (TP) points. Other variables included radiation dose, efficiency, and complications. Results: Twenty-seven patients (13 CT and 14 XT) underwent placement of SEEG electrodes (319 in total). The mean EP and TP errors for the CT group were 2.3 mm and 3.3 mm, respectively, and 1.9 mm and 2.9 mm for the XT group, with no statistical difference (p = 0.75 and p = 0.246). The time to first electrode placement was similar (XT, 82 ± 10 min; CT, 84 ± 22 min; p = 0.858) and the average radiation exposure with XT (234 ± 55 mGy*cm) was significantly lower than CT (1245 ± 123 mGy*cm) (p < 0.0001). Four complications were documented with equal incidence in both groups. Conclusions: The use of XT as a method for registration resulted in similar implantation accuracy compared with CT. Advantages of XT are the substantial reduction in radiation dose and the elimination of the need to transfer the patient out of the room which may have an impact on patient safety and OR efficiency.

Idioma originalEnglish
Páginas (desde-hasta)1347-1354
Número de páginas8
PublicaciónActa Neurochirurgica
Volumen163
N.º5
DOI
EstadoPublished - may. 2021
Publicado de forma externa

Nota bibliográfica

Publisher Copyright:
© 2021, The Author(s), under exclusive licence to Springer-Verlag GmbH, AT part of Springer Nature.

ASJC Scopus Subject Areas

  • Surgery
  • Clinical Neurology

PubMed: MeSH publication types

  • Journal Article
  • Validation Study

Huella

Profundice en los temas de investigación de 'Validation of 3D fluoroscopy for image-guidance registration in depth electrode implantation for medically refractory epilepsy'. En conjunto forman una huella única.

Citar esto