TY - JOUR
T1 - Initial human feasibility of infusion needle catheter ablation for refractory ventricular tachycardia
AU - Sapp, John L.
AU - Beeckler, Christopher
AU - Pike, Robert
AU - Parkash, Ratika
AU - Gray, Christopher J.
AU - Zeppenfeld, Katja
AU - Kuriachan, Vikas
AU - Stevenson, William G.
PY - 2013/11/19
Y1 - 2013/11/19
N2 - BACKGROUND - : Ablation of ventricular tachycardia (VT) is sometimes unsuccessful when ablation lesions are of insufficient depth to reach arrhythmogenic substrate. We report the initial experience with the use of a catheter with an extendable/retractable irrigated needle at the tip capable of intramyocardial mapping and ablation. METHODS AND RESULTS - : Sequential consenting patients with recurrent VT underwent ablation with the use of a needle-tipped catheter. At target sites, the needle was advanced 7 to 9 mm into the myocardium, permitting pacing and recording. Infusion of saline/iodinated contrast mixture excluded perforation and ensured intramyocardial deployment. Further infusion was delivered before and during temperature-controlled radiofrequency energy delivery through the needle. All 8 patients included (6 male; mean age, 54) with a mean left ventricular ejection fraction of 29% were refractory to multiple antiarrhythmic drugs, and 1 to 4 previous catheter ablation attempts (epicardial in 4) had failed. Patients had 1 to 7 (median, 2) VTs present or inducible; 2 were incessant. Some intramyocardial VT mapping was possible in 7 patients. A mean of 22 (limits, 3-48) needle ablation lesions were applied in 8 patients. All patients had at least 1 VT terminated or rendered noninducible. During a median of 12 months follow-up, 4 patients were free of recurrent VT, and 3 patients were improved, but had new VTs occur at some point during follow-up. Two died of the progression of preexisting heart failure without recurrent VT. Complications included tamponade in 1 patient and heart block in 2 patients. CONCLUSIONS - : Intramyocardial infusion-needle catheter ablation is feasible and permits control of some VTs that have been refractory to conventional catheter ablation therapy, warranting further study.
AB - BACKGROUND - : Ablation of ventricular tachycardia (VT) is sometimes unsuccessful when ablation lesions are of insufficient depth to reach arrhythmogenic substrate. We report the initial experience with the use of a catheter with an extendable/retractable irrigated needle at the tip capable of intramyocardial mapping and ablation. METHODS AND RESULTS - : Sequential consenting patients with recurrent VT underwent ablation with the use of a needle-tipped catheter. At target sites, the needle was advanced 7 to 9 mm into the myocardium, permitting pacing and recording. Infusion of saline/iodinated contrast mixture excluded perforation and ensured intramyocardial deployment. Further infusion was delivered before and during temperature-controlled radiofrequency energy delivery through the needle. All 8 patients included (6 male; mean age, 54) with a mean left ventricular ejection fraction of 29% were refractory to multiple antiarrhythmic drugs, and 1 to 4 previous catheter ablation attempts (epicardial in 4) had failed. Patients had 1 to 7 (median, 2) VTs present or inducible; 2 were incessant. Some intramyocardial VT mapping was possible in 7 patients. A mean of 22 (limits, 3-48) needle ablation lesions were applied in 8 patients. All patients had at least 1 VT terminated or rendered noninducible. During a median of 12 months follow-up, 4 patients were free of recurrent VT, and 3 patients were improved, but had new VTs occur at some point during follow-up. Two died of the progression of preexisting heart failure without recurrent VT. Complications included tamponade in 1 patient and heart block in 2 patients. CONCLUSIONS - : Intramyocardial infusion-needle catheter ablation is feasible and permits control of some VTs that have been refractory to conventional catheter ablation therapy, warranting further study.
UR - http://www.scopus.com/inward/record.url?scp=84888201180&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84888201180&partnerID=8YFLogxK
U2 - 10.1161/CIRCULATIONAHA.113.003423
DO - 10.1161/CIRCULATIONAHA.113.003423
M3 - Article
C2 - 24036605
AN - SCOPUS:84888201180
SN - 0009-7322
VL - 128
SP - 2289
EP - 2295
JO - Circulation
JF - Circulation
IS - 21
ER -