Normal visual fields measured with Octopus Program G1 - I. Differential light sensitivity at individual test locations

Mario Zulauf, M. Zulauf, Josef Flammer, R. P. LeBlanc

Résultat de recherche: Articleexamen par les pairs

26 Citations (Scopus)

Résumé

Exact knowledge of the normal variation of visual fields and the influence of age upon them is essential to differentiate normal from abnormal results, e.g., in glaucoma suspects. This study evaluates the normal variability of differential light sensitivity at individual test locations and incorporates a data base of a multicenter study performed with Octopus 201 perimeters using Program G1. The 824 fields thus obtained included 139 fields of 139 healthy volunteers who had undergone two previous visual fields and completed all three phases of the program. Sensitivity decreased linearly with age, an effect which for individual test locations ranged between 0.036 and 0.107 dB/year and which became more pronounced towards the periphery. On average, the age-related effects explained only 17% of the interindividual variation (range 4%-31%). The interindividual variation within a test averaged 4.6 dB2 and revealed a moderate, but quadratic increase towards the periphery. The intra-individual short-term variation was considerably lower, averaging 2.2 dB2. There was a similar modest, quadratic increase of the intra-individual variation towards the periphery. The results may help distinguish incipient disease manifestations from normal variation of perimetric results. Furthermore, the results give insight into the calculation of global visual field indices.

Langue d'origineEnglish
Pages (de-à)509-515
Nombre de pages7
JournalGraefe's Archive for Clinical and Experimental Ophthalmology
Volume232
Numéro de publication9
DOI
Statut de publicationPublished - sept. 1994
Publié à l'externeOui

ASJC Scopus Subject Areas

  • Ophthalmology
  • Sensory Systems
  • Cellular and Molecular Neuroscience

PubMed: MeSH publication types

  • Journal Article
  • Multicenter Study
  • Research Support, Non-U.S. Gov't

Empreinte numérique

Plonger dans les sujets de recherche 'Normal visual fields measured with Octopus Program G1 - I. Differential light sensitivity at individual test locations'. Ensemble, ils forment une empreinte numérique unique.

Citer

Zulauf, M., Zulauf, M., Flammer, J., & LeBlanc, R. P. (1994). Normal visual fields measured with Octopus Program G1 - I. Differential light sensitivity at individual test locations. Graefe's Archive for Clinical and Experimental Ophthalmology, 232(9), 509-515. https://doi.org/10.1007/BF00181992