Optimization of a passive sampling method for determination of airborne naphthalene for residential indoor air monitoring

Amanda J. Wheeler, Phil Fellin, Henrik Li, Mark D. Gibson, Judy Read Guernsey, Keith Van Ryswsk, Leonora Marro, Huda Masoud, Roger Sutcliffe, Marie Eve Héroux

Résultat de recherche: Conference contribution

2 Citations (Scopus)

Résumé

Several exposure studies of indoor air contaminants have used passive sampling devices (PSDs) to determine VOC levels. An existing passive method to determine airborne naphthalene at low levels offers reproducible but low recoveries, considered unacceptable for producing quantitative results. Given the need to determine airborne naphthalene quantitatively with high sensitivity and high quality, optimization of the passive sampling method was undertaken. Seven solvent combinations were evaluated to determine the extraction efficiency, toluene being the most promising. Detailed assessments of toluene extracts allowed optimization of chromatographic performance and characterization of the new method. Passive sampling was then conducted as part of an indoor air exposure study in up to 6 locations within residences including the living room, garage, basement, bathroom, main bedroom and kitchen for both 7-day and 24-hr integrated samples. Results indicate summer naphthalene concentrations were highest in the garage, followed by the basement and then living room.

Langue d'origineEnglish
Titre de la publication principale12th International Conference on Indoor Air Quality and Climate 2011
Pages1183-1188
Nombre de pages6
Statut de publicationPublished - 2011
Événement12th International Conference on Indoor Air Quality and Climate 2011 - Austin, TX, United States
Durée: juin 5 2011juin 10 2011

Séries de publication

Prénom12th International Conference on Indoor Air Quality and Climate 2011
Volume2

Conference

Conference12th International Conference on Indoor Air Quality and Climate 2011
Pays/TerritoireUnited States
VilleAustin, TX
Période6/5/116/10/11

ASJC Scopus Subject Areas

  • Pollution

Empreinte numérique

Plonger dans les sujets de recherche 'Optimization of a passive sampling method for determination of airborne naphthalene for residential indoor air monitoring'. Ensemble, ils forment une empreinte numérique unique.

Citer

Wheeler, A. J., Fellin, P., Li, H., Gibson, M. D., Guernsey, J. R., Van Ryswsk, K., Marro, L., Masoud, H., Sutcliffe, R., & Héroux, M. E. (2011). Optimization of a passive sampling method for determination of airborne naphthalene for residential indoor air monitoring. Dans 12th International Conference on Indoor Air Quality and Climate 2011 (pp. 1183-1188). (12th International Conference on Indoor Air Quality and Climate 2011; Vol. 2).