Résumé
Simulation of the commonly constructed geometries of aorto-coronary bypass anastomoses was carried out using especially fabricated distensible tubes and a pulsatile pump. The system pressure was maintained between 80 and 120 mm Hg. The total mean flow was set at 250 ml min-1 (Reynolds number of 200) and the pulsatile frequency was varied from 0 to 2 Hz. A water-glycerine mixture having a density and viscosity similar to that of blood was used throughout. A 16 mm film of the front of black dye injected proximal to the anastomosis was made as the dye approached and passed through the anastomosis. Anastomotic geometries consisted of: end to side, parallel, 45° angle, and 90° angle. Stenoses, located in the tube representing the coronary artery, were simulated using a bevelled insert which represented an 80-85% area reduction. Flow visualization revealed that distensible tubes gave more realistic flow patterns than rigid tubes, a result particularly evident when a stenosis was present. Pulsatile flow demonstrated considerably more mixing than steady flow. The use of pulsatile flow in distensible tubing with a partial stenosis showed retrograde flow through the stenosis which was not evident for either steady flow or for flow in rigid tubing. The flow at the anastomatic site of the graft having an angle of 0° showed a jetting action with a zone of recirculating fluid being present whereas for a 90 degree graft a distinct helical flow was formed distal to the anastomosis.
Langue d'origine | English |
---|---|
Pages (de-à) | 491-499 |
Nombre de pages | 9 |
Journal | Journal of Biomechanics |
Volume | 19 |
Numéro de publication | 7 |
DOI | |
Statut de publication | Published - 1986 |
ASJC Scopus Subject Areas
- Biophysics
- Orthopedics and Sports Medicine
- Biomedical Engineering
- Rehabilitation