Intra and inter technologist variability in the quality assessment of respiratory tract specimens

Geraldine M. Cooper, Janice J. Jones, Judy C. Arbique, Gordon J. Flowerdew, Kevin R. Forward

Research output: Contribution to journalArticlepeer-review

19 Citations (Scopus)

Abstract

The majority of microbiology laboratories have implemented quality improvement procedures such as a Q scoring system to assess the nature of clinical specimens. Our study reviewed the sources and the amount of variation when Q scoring of lower respiratory secretions was performed. In total, 450 slides representing lower respiratory tract secretions were Q scored by three experienced technologists. Total agreement regarding the number of neutrophils, squamous epithelial cells and Q scores was 76%, 57% and 57% respectively. The major factor influencing Q score values was the enumeration of epithelial cells. From our findings, we expect that there is greater variability in Q scoring then is generally acknowledged and there is a substantial degree of subjectivity on part of individual technologists reading gram stains. (C) 2000 Elsevier Science Inc.

Original languageEnglish
Pages (from-to)231-235
Number of pages5
JournalDiagnostic Microbiology and Infectious Disease
Volume37
Issue number4
DOIs
Publication statusPublished - Aug 2000

ASJC Scopus Subject Areas

  • Microbiology (medical)
  • Infectious Diseases

PubMed: MeSH publication types

  • Journal Article

Fingerprint

Dive into the research topics of 'Intra and inter technologist variability in the quality assessment of respiratory tract specimens'. Together they form a unique fingerprint.

Cite this