TY - JOUR
T1 - Diffusion-Weighted Magnetic Resonance Imaging of Cholesteatoma Using PROPELLER at 1.5T
T2 - A Single-Centre Retrospective Study
AU - Clarke, Sharon E.
AU - Mistry, Dipan
AU - AlThubaiti, Talal
AU - Khan, M. Naeem
AU - Morris, David
AU - Bance, Manohar
N1 - Publisher Copyright:
© 2016 Canadian Association of Radiologists
PY - 2017/5
Y1 - 2017/5
N2 - Purpose The purpose of this study was to evaluate the sensitivity, specificity, and positive and negative predictive values of the diffusion-weighted periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique in the detection of cholesteatoma at our institution with surgical confirmation in all cases. Methods A retrospective review of 21 consecutive patients who underwent diffusion-weighted PROPELLER magnetic resonance imaging (MRI) on a 1.5T MRI scanner prior to primary or revision/second-look surgery for suspected cholesteatoma from 2009-2012 was performed. Results Diffusion-weighted PROPELLER had a sensitivity of 75%, specificity of 60%, positive predictive value of 86%, and negative predictive value of 43%. In the 15 patients for whom the presence or absence of cholesteatoma was correctly predicted, there were 2 cases where the reported locations of diffusion restriction did not correspond to the location of the cholesteatoma observed at surgery. Conclusion On the basis of our retrospective study, we conclude that diffusion-weighted PROPELLER MRI is not sufficiently accurate to replace second look surgery at our institution.
AB - Purpose The purpose of this study was to evaluate the sensitivity, specificity, and positive and negative predictive values of the diffusion-weighted periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique in the detection of cholesteatoma at our institution with surgical confirmation in all cases. Methods A retrospective review of 21 consecutive patients who underwent diffusion-weighted PROPELLER magnetic resonance imaging (MRI) on a 1.5T MRI scanner prior to primary or revision/second-look surgery for suspected cholesteatoma from 2009-2012 was performed. Results Diffusion-weighted PROPELLER had a sensitivity of 75%, specificity of 60%, positive predictive value of 86%, and negative predictive value of 43%. In the 15 patients for whom the presence or absence of cholesteatoma was correctly predicted, there were 2 cases where the reported locations of diffusion restriction did not correspond to the location of the cholesteatoma observed at surgery. Conclusion On the basis of our retrospective study, we conclude that diffusion-weighted PROPELLER MRI is not sufficiently accurate to replace second look surgery at our institution.
UR - http://www.scopus.com/inward/record.url?scp=84992699386&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84992699386&partnerID=8YFLogxK
U2 - 10.1016/j.carj.2016.05.002
DO - 10.1016/j.carj.2016.05.002
M3 - Article
C2 - 27625184
AN - SCOPUS:84992699386
SN - 0846-5371
VL - 68
SP - 116
EP - 121
JO - Canadian Association of Radiologists Journal
JF - Canadian Association of Radiologists Journal
IS - 2
ER -